Detection of microaneurysms using multi-scale correlation coefficients

作者:

Highlights:

摘要

This paper presents a new approach to the computer aided diagnosis (CAD) of diabetic retinopathy (DR)—a common and severe complication of long-term diabetes which damages the retina and cause blindness. Since microaneurysms are regarded as the first signs of DR, there has been extensive research on effective detection and localization of these abnormalities in retinal images. In contrast to existing algorithms, a new approach based on multi-scale correlation filtering (MSCF) and dynamic thresholding is developed. This consists of two levels, microaneurysm candidate detection (coarse level) and true microaneurysm classification (fine level). The approach was evaluated based on two public datasets—ROC (retinopathy on-line challenge, http://roc.healthcare.uiowa.edu) and DIARETDB1 (standard diabetic retinopathy database, http://www.it.lut.fi/project/imageret/diaretdb1). We conclude our method to be effective and efficient.

论文关键词:Computer-aided diagnosis (CAD),Diabetic retinopathy (DR),Multi-scale correlation filtering,Microaneurysm (red lesion) detection

论文评审过程:Received 6 October 2008, Revised 8 November 2009, Accepted 28 December 2009, Available online 7 January 2010.

论文官网地址:https://doi.org/10.1016/j.patcog.2009.12.017