Enhanced FEM-based modeling of brain shift deformation in Image-Guided Neurosurgery

作者:

Highlights:

摘要

We consider the problem of improving outcomes for neurosurgery patients by enhancing intraoperative navigation and guidance. Current navigation systems do not accurately account for intraoperative brain deformation. We focus on the brain shift deformation that occurs just after the opening of the skull and dura. The heart of our system is a nonrigid registration technique using a biomechanical model. We specifically work on two axes: the representation of the structures in the biomechanical model and the evaluation of the surface landmark displacement fields between intraoperative MR images. Using the modified Hausdorff distance as an image similarity measure, we demonstrate that our approach significantly improves the alignment of the intraoperative images.

论文关键词:Nonrigid registration,Intraoperative MR,Brain shift,FEM,Biomechanical model

论文评审过程:Received 30 September 2008, Revised 10 May 2009, Available online 15 August 2009.

论文官网地址:https://doi.org/10.1016/j.cam.2009.08.062